6.2.14 TIMED

BLOWER

Your remote system may have a built in timer (in thermostat mode) that enables the blower (if equipped) to
cycle on and off automatically when the burner turns on and off. With the remote control fan speed preset at
the preferred speed, the blower will come on approximately 5 minutes after the main burner comes on and will
shut off approximately 12 minutes after the burner shuts off.
This time delay is designed to maximize the blower distribution of heated air.
If at any time the burner re-ignites before the twelve minutes are over, the fan will continue to run.

NOTE: At any time in the sequence, the blower (if equipped) can be manually turned on/off using the
remote control.

35.19B

RIGHT SIDE OF

DOOR FRAME

(OPERATING SIDE)

ANTI CONDENSATION

CONTROL SWITCH

This appliance has the option to go from an electronic intermittent
pilot ignition to a standing pilot for cold climates.