5.0 ELECTRICAL INFORMATION

5.1 WIRING

DIAGRAM

!

WARNING

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED

SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE

ELECTRICAL CIRCUIT.

RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE

APPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS.

ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE

WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN

ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN

THE UNITED STATES.

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,

WITH THE GLASS DOOR OPENED OR REMOVED.

69.2

Wire Harness Assembly

IPI Board

Pilot

Ground

Wire

EI

Pilot

Spark Electrode

Flame

Sensor

Valve

Electronic Modulation

120V OUT

FAN

AUX OUT

COM

POWER

ACS/IPI Switch

(OPTIONAL)

Receiver

Wire Harness

Control Module

Night Lights

Fan

(OPTIONAL)

Wire

Harness

Plug

This appliance comes equipped with a battery back-up. If this back-up is used, install 4 AA batteries (not
supplied) into the receiver.