Napoleon Fireplaces Castlemore GDS26 Manuel d'utilisation

Page 39

Advertising
background image

39

W415-0827 / D / 08.10.12

9.3 FLAME

CHARACTERISTICS

It’s important to periodically perform a visual check of the pilot and burner
fl ames. Compare them to the illustrations provided. If any fl ames appear abnor-
mal call a service person.

54.3

9.4 VENTURI

ADJUSTMENT

This appliance has an air shutter that has been factory set open according
to the chart below:

Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!

AIR
SHUTTER
OPENING

VENTURI
BURNER

ORIFICE

49.1

GDS26

NG

3/16”

LP

3/8”

9.5 RESTRICTING VERTICAL VENTS

77.3

Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must
be restricted using a restrictor vent kit. Refer to “ACCESORIES” in the “REPLACEMENTS” section for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating
a more traditional gentle fl ame appearance. Specifi c instructions are included with the kit.