20

W415-0827 / D / 08.10.12

Example:
V

1

= 1.5 FT

V

2

= 5 FT

V

T

= V

1

+ V

2

= 1.5 + 1 + 5 = 6.5 FT

H

1

= 1 FT

H

2

= 1 FT

H

3

= 10.75 FT

H

R

= H

1

+ H

2

+ H

3

= 1 + 1 + 10.75 = 12.75 FT

H

O

= .03 (four 90° elbows + one 45° elbow - 90°)

= .03 (360° + 45° - 90°) = 6.75 FT
H

T

= H

R

+ H

O

= 12.75 + 6.75 = 19.5 FT

H

T

+ V

T

= 19.5 + 6.5 = 26 FT

Formula 1:
H

T

< 3 V

T

3 V

T

= 3 x 6.5 = 19.5 FT

19.5 = 19.5

Formula 2:
H

T

+ V

T

< 40 FT

26 < 40

Since both formulas are met, this vent configuration is acceptable.

90°

V

1

V

2

H

1

H

2

90°

90°

H

3

45°

18.2_3