0 electrical connection, 1 wiring diagram, The main burner on/off switch and night light – Napoleon Fireplaces Castlemore GDS26 Manuel d'utilisation

Page 32

Advertising
background image

32

W415-0827 / D / 08.10.12

5.0 ELECTRICAL CONNECTION

5.1 WIRING

DIAGRAM

B

URNER

M

AIN

S

WITCH

B

ATTERY

H

OLDER

G

AS

V

ALVE

P

ILOT

A

SSEMBLY

I

GNITION

M

ODULE

P

ILOT

G

AS

L

INE

Orange
(I)

[through

independent

conduit]

Yellow
(S)

[through
Gas line

conduit]

AC A

DAPTOR

B

ATTERY

R

ELAY

Red (3 Volt)

Red

Black

W

IRE

H

ARNESS

Brown
(SWI)

Black
(-)

Red
(+)

Green x2
(TH)

Orange x2
(THTP)

Black

Yellow

Blue

Black
(TP)

M

ODULE

P

LUG

R

ELAY

P

LUG

Black

Green

Orange

Black (12 Volt)
To Night Light &
Accent Light Switch

To

Optional

Switch

The main burner on/off switch and Night Light

TM

switch is located behind lower access panel. For ease of

accessibility, optional remote wall switches may be installed in a convenient location for both burner and light

operation.

The recommended maximum lead length depends on wire size:

WIRE SIZE

MAX. LENGTH

14

gauge

100

feet

16 gauge

60 feet

18 gauge

40 feet

Route 2-strand (solid core) wire through the electrical hole located at the bottom left side of the appliance.

Connect the wires from the wall switch to the two corresponding spade connectors on the back of the on/off

switches located behind the lower access panel.

Advertising