Napoleon Fireplaces NPI45 Manuel d'utilisation

Page 35

Advertising
background image

W415-0702 / B / 04.04.12

35

8.7 INSTALLING A THERMOSTAT OR REMOTE CONTROL

8.8 SHUTDOWN

INSTRUCTIONS

Push the "ON/OFF" button. Your appliance will cycle down and the blower will remain operating until your
appliance has cooled.

An optional millivolt thermostat is available to help keep the room temperature constant.

NOTE: The thermostat must be installed by a qualifi ed installer.

A.

Disconnect the power supply.

B.

Remove the right side panel to gain access to the rear of the control panel.

C.

Strip and connect the thermostat wires to the screw terminals on the back of the control panel.

D.

Route the thermostat wire through the space between the fi rebox base and the right side panel.

NOTE: The control must be in either T-STAT or AUTO to control the appliance with a thermostat.

SCREW
TERMINALS

Advertising