3.3 STOVE MINIMUM CLEARANCE TO COMBUSTIBLES

Through the Wall Installations complete

with outside air

Interior Vertical Vents

3.3.1 STRAIGHT INSTALLATION

DO NOT INSTALL INTO ANY AREA HAVING LESS THAN 48" (CEILING TO APPLIANCE BOTTOM,

EXCLUDING HEARTH HEIGHT).

!

WARNING

Through the Wall Vents complete with outside air

Interior Vertical Vents

NOTE: If interior vertical pellet vent is used, the clearance to the back wall is determined by the up-
ward-turning elbow or "Tee". It will vary in depth depending on the brand of pellet vent used (it is ap-
proximately 5"). Before placing the appliance, connect the elbow or "Tee" and allow for the minimum
3" clearance to the combustible wall.

3.3.2 CORNER INSTALLATION

2”

6”

Floor Protection

45°

2”

2”

6”

6”