Napoleon Fireplaces GSS42 Manuel d'utilisation

Page 9

Advertising
background image

9

W415-0617 / E / 06.13.12

It is best to frame your appliance after it is positioned. Use 2x4’s and frame to local building codes.

Minimum Clearance to Combustibles construction from appliance and vent surfaces:
Framing 0” to stand-offs (rear and sides only)

Use a steel header for the top and two steel studs on the sides.

Finishing 1” to back and sides
Non-combustible fi nishing 18” to top

4” to sides of appliance opening
Non-combustible fi nishing material (ie. cement board, brick, stone, tile) may
be used to fi nish the front of the appliance.

Recessed depth 22 1/4“
Enclosure top 58 1/2” from bottom of appliance
Clearance to ceiling 84” from bottom of appliance.

It is recommended that the walls of the appliance enclosure be fi nished. This would ensure that clearance to
combustibles is maintained within the cavity.