Warning, 0 adjustment – Napoleon Fireplaces GSS42 Manuel d'utilisation

Page 17

Advertising
background image

17

W415-0617 / E / 06.13.12

It’s important to periodically perform a visual check of the pilot and
burner fl ames. Compare them to the illustrations provided. If any fl ames
appear abnormal call a service person.

54.2

3/8” - 1/2”

FLAME MUST

ENVELOP UPPER

3/8" TO 1/2" OF

THERMOCOUPLE &

THERMOPILE

8.0 ADJUSTMENT

8.1 VENTURI

ADJUSTMENT

CARBON CAN BE DISTRIBUTED IN SURROUNDING LIVING AREA IF THE AIR SHUTTER IS

IMPROPERLY ADJUSTED.

!

WARNING

49.5

This appliance has an air shutter that has been factory set open according
to the chart below:

Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!

AIR
SHUTTER
OPENING

VENTURI
BURNER

ORIFICE

49.1

GSS42

NG

1/8”

LP

1/4”

8.2 FLAME

CHARACTERISTICS

Advertising