For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient
location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The
recommended maximum lead length depends on wire size:

WIRE SIZE

MAX. LENGTH

14

gauge

100

feet

16 gauge

60 feet

18 gauge

40 feet

Disconnect the existing wires from terminals 1 and 3 (from the
ON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.

50.3

PIL

O

T

!

WARNING

DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110

VOLT ELECTRICITY.

TP

3.2 GAS INLET LOCATIONS

3.3 OPTIONAL WALL SWITCH INSTALLATION

7

1

/

8

"

"

15

5

/

16

7

1

/

8

"

"

14

"

23

5

/

16

16

1

/

16

"

There are fi ve gas inlet locations on the ventless fi rebox enclosure. One on each side of the appliance, two
at the rear, and one on the bottom. Using the following illustrations identify the preferred inlet and remove
corresponding knock out.