Warning, 3 minimum mantel clearances, 4 nailing tab – Napoleon Fireplaces GSS42 Manuel d'utilisation

Page 11

Advertising
background image

11

W415-0617 / E / 06.13.12

!

WARNING

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE

TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO

OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE

CLEARLY MAINTAINED.

WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE

HEAT RESISTANT TO PREVENT DISCOLOURATION.

73.1

4.3 MINIMUM MANTEL CLEARANCES

We recommend all mantels made from non-combustible material. If using combustible materials, follow the
chart below.

NOTE: Mantel temperatures will rise above normal temperatures
and may be hot to the touch.

4.4 NAILING

TAB

TOP OF

FIREPLACE

8” MANTEL

6”

4”

2”

30”28”

26”

24”

35 3/4”

28

26

24

4

2

30

32

8

6

10

MANTEL

DEPTH

MANTEL

HEIGHT

To install the appliance face fl ush with the fi nished
surface, position the framework to accommodate the
thickness of the fi nished surface. Bend out the six
nailing tabs, attached on top and on either side of the
appliance and secure to the 2x4 framing. The tabs will
facilitate the installation of either a

1

/

2

” or

3

/

4

” fi nished

surface thickness.