Napoleon Fireplaces Swarovski - LHD50SS Manuel d'utilisation

Page 7

Advertising
background image

7

W415-0839 / D / 08.15.12

When the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommendations from the
local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each ad-
ditional 1,000ft. Expansion / contraction noises during heating up and cooling down cycles are normal and are to
be expected. Change in fl ame appearance from “HI” to “LO” is more evident in natural gas than in propane.

This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mobile
home installation.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.

There are two switches that control the function of the appliance. One on the receiver that must be placed in
the middle position. The other is on the control module that must be in the “I” position, which denotes on. If
these switches aren’t in these locations the appliance will not work, see “REMOTE RECEIVER INSTALLA-
TION” and “CONTROL MODULE” section.

NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature
but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.

This appliance is equipped with a remote control system, which requires batteries (supplied) to be installed.
The transmitter takes 3 “AAA” batteries and in the case of a power failure the receiver takes 4 “AA” batteries.

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!

LHD50

NG

LP

Altitude (FT)

0-4,500

0-4500

Max. Input (BTU/HR)

30,000

30,000

Max. Output (BTU/HR)

24,000

24,000

Effi ciency

79%

79%

Min. Inlet Gas Supply Pressure

4.5" Water Column

11" Water Column

Max. Inlet Gas Supply Pressure

7" Water Column

13" Water Column

Manifold Pressure (Under Flow Conditions)

3.5" Water Column

10" Water Column

2.3 GENERAL

INFORMATION

Advertising