SYMPTOM

PROBLEM

TEST SOLUTION

Exhaust fumes
smelled in room,
headaches.

Appliance is spilling.

-

Check door seal.

-

Check for exhaust damage.

-

Check that venting is installed correctly.

-

Room is in negative pressure; increase fresh air supply.

Pilot will not light.
Makes noise with
no spark at pilot
burner.

Wiring.

-

Verify the wire for the sensor and the wire for the ignitor
are connected to the correct terminals (not reverse) on
the module and pilot assembly.

Loose connection.

-

Verify no loose connections, electrical shorts in the
wiring or ground out to any metal object.

Igniter Spark gap is
incorrect.

-

Spark gap of the ignitor to the pilot should be .125”
(1/8”).

Pilot will not light.

Makes no noise

with no spark

at pilot burner.

Crystalites™ and

(optional) blower

operates.

A shorted or loose

connection.

-

Remove and reinstall the wiring harness that plugs into

the module.

-

Remove and verify continuity of each wire in the wiring

harness.

Module is not grounded.

-

Verify the valve and pilot assemblies are properly

grounded to the metal chassis of the fi replace.

Ignition box has been

locked out.

Choose one of the 4 methods below to reset the system.
1.

To reset ignition box when locked out. Turn off power

supply and remove batteries (if used) from the back up

battery pack.

2.

To reset the DFC Board when the board goes into a

lock out condition and the LED is blinking 3 times using

the transmitter ON/OFF button:

Step 1:

Turn the system off by pressing the ON/

OFF button to turn the system off.
Step 2:

After approximately 2 seconds press the

ON/OFF button on the transmitter again. THE DFC

Board will reset and the ignition sequence will start

again.

3.

To reset the DFC Board when the board goes into a

lock out condition and the LED is blinking 3 times by

cycling fl ame:

Step 1:

In the manual fl ame control mode, use

the down arrow button to reduce the fl ame to

off, indicated by the word OFF displayed on the

trasmitter LCD screen.
Step 2:

Wait approximately 2 seconds and press

the up arrow button, the ignition sequence will

start.

NOTE: Starting from OFF, press the ON button on the transmitter. Approximately 4
seconds after the ON/OFF button is pressed the ignition board will start the spark.
The fi rst try for ignition will last approximately 60 seconds. If there is no fl ame ignition
(rectifi cation) the board will stop sparking for approximately 35 seconds. After the
wait time the board will start the second try for ignition by sparking for approximately
60 seconds. If there is still no positive ignition, the board will go into lock out.

42.1_2A