Napoleon Fireplaces Swarovski - LHD50SS Manuel d'utilisation

Page 49

Advertising
background image

49

W415-0839 / D / 08.15.12

10.3 VENTURI ADJUSTMENT

VENTURI ADJUSTMENT CHART

FUEL

LHD50SS

NG

1/8”

LP

1/4”

This appliance has an air shutter that has been factory set open according
to the chart below:

Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!

AIR
SHUTTER
OPENING

VENTURI
BURNER

ORIFICE

49.1

10.4 FLAME CHARACTERISTICS

It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the
illustration provided. If any fl ames appear abnormal call a service person.

FLAME MUST ENVELOP
UPPER 3/8” TO 1/2” OF
FLAME SENSOR

PILOT

BURNER

ELECTRODE

FLAME

SENSOR

54.1A

Advertising