A.

Remove the valve train assembly and set aside, see “VALVE
TRAIN ASSEMBLY” section. Disconnect the wires to the control
module, labeling one end to aid with their re-connection.

B.

Remove the 4 screws holding the control module shield in place.

C.

Remove the 2 screws holding the control module in place, unplug
and remove.

D.

Replace and reinstall components.

NOTE: Control module ON/OFF switch should always be in the “ON” position. If for any reason the
module is turned “OFF”, the components plugged into the module won’t have power.

11.5 BURNER REMOVAL

CONTROL

MODULE SHIELD

11.6 CONTROL MODULE REMOVAL

A.

Remove the valve train assembly and set aside, see “VALVE TRAIN ASSEMBLY” section. Disconnect
the wires to the control IPI Board and/or the AC Adaptor, see CONTROL ACCESS” section for
components locations.

Label one end of each wire to aid with their re-connection.

Components are held in place with velcro. Pull off and replace components as required.

11.7 IPI BOARD AND AC ADAPTOR ACCESS

MEDIA TRAY

BURNER

SCREWS

A.

Remove the glass door, see “DOOR / REMOVAL
INSTALLATION” section.

B.

Remove the 2 screws that secure the pilot shield in
place. Lift the pilot shield off the media tray.

C.

Remove the 16 screws (8 per side) that secure the
media tray in place. Lift the tray up and out.

D.

Remove the 8 screws that secure the burner in place.
Lift the burner up and out.