Napoleon Fireplaces Vector 50 - LHD50 Manuel d'utilisation

Page 33

Advertising
background image

33

W415-0745 / F / 08.26.13

EN

* Within the appliance enclosure a 6” (152mm) clearance between the top of the vent pipe and combustible
materials is required. All other clearances within the enclosure, including where the vent pipe exits the
enclosure are subject to 2” (51mm) to the sides and bottom and 3” (76mm) to the top for horizontal and 1”
(25mm) for vertical.
** See venting section.

2"

51mm

6"

152mm

6"

152mm *

0” IF NON-COMBUSTIBLE

FINISHING IS USED SUCH

AS BRICK AND STONE.

3"

76mm

51"

1295mm

MINIMUM

PLUS RISE**

NON-COMBUSTIBLE

COMBUSTIBLE

TOP OF ENCLOSURE

(COMBUSTIBLE)

STEEL STUD

FRAME

32"

813mm

MINIMUM

TOP OF

APPLIANCE

OPENING

28"

711mm

MINIMUM

60"

1524mm

MINIMUM

ENCLOSURE

HEIGHT