Stretch the inner fl ex pipe to the required

length needed for the fi nished wall surface.

Apply a heavy bead of high temperature

sealant W573-0007 Mill Pac (not supplied) to

the inner sleeve of the air terminal. Slip the

vent pipe a minimum of 2” (50.8mm) over the

inner sleeve of the air terminal and secure

with 3 #8 screws.

B.

Using the outer fl ex pipe, slide over the outer

combustion air sleeve of the air terminal

and secure with 3 #8 screws. Seal using

high temperature sealant W573-0002 (not

supplied).

C.

Insert the vent pipes through the fi restop

maintaining the required clearance to

combustibles. Holding the air terminal (lettering

in an upright, readable position), secure to the

exterior wall and make weather tight by sealing

with caulking (not supplied).

D.

If more vent pipe needs to be used to

reach the fi replace, couple them together

as illustrated. The vent system must be

supported approximately every 3 feet (0.9mm)

for both vertical and horizontal runs. Use

noncombustible strapping to maintain the

minimum 1” (25.4mm) clearance to combustibles.

The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the depth
of its return fl ange.

23.3B

HI-TEMP

SEALANT

#8 X 1/2” SELF DRILLING

SCREWS & WASHERS

INNER COUPLER

OUTER COUPLER

OUTER

FLEX PIPE

INNER
FLEX PIPE

OUTER

FLEX PIPE

CAULKING

SCREWS

#10x2"

PIPE

OUTER FLEX

SEALANT

2" (50.8mm) OVERLAP

HI-TEMP

INNER FLEX

PIPE

4.2.1 HORIZONTAL AIR TERMINAL INSTALLATION