Warning – Napoleon Fireplaces Vector 50 - LHD50 Manuel d'utilisation

Page 32

Advertising
background image

32

W415-0745 / F / 08.26.13

ENEN

* Within the appliance enclosure a 6” (152mm) clearance between the top of the vent pipe and combustible
materials is required. All other clearances within the enclosure, including where the vent pipe exits the enclo-
sure are subject to 2” (51mm) to the sides and bottom and 3” (76mm) to the top for horizontal and 1” (25mm)
for vertical.
** See venting section.

IMPORTANT:

The LHD50 requires a minimum inside enclosure height of 60” (1524mm), measured from the

bottom of the appliance. For temperature requirements, this area must be left unobstructed. It is recommended
that the enclosure be ventilated at the top and bottom to circulate the hot air.

Before fi nishing in the appliance test the operation using the remote control, cycling it through all of its different

modes, see “OPERATION” section. Check pressure readings, see “PILOT BURNER ADJUSTMENT” section.

Once fi nished in, access to the control components can only be done through the inside of the appliance.

5.3 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

!

WARNING

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., AS LONG AS THESE MATERIALS NEVER OVERHANG

INTO THE APPLIANCE OPENING.

60"

1524mm

MINIMUM

ENCLOSURE

HEIGHT

TOP OF

APPLIANCE

OPENING

32"

813mm

MINIMUM

28"

711mm

MINIMUM

COMBUSTIBLE

MATERIAL

NON-COMBUSTIBLE

STEEL STUD

FRAME

COMBUSTIBLE

NON-COMBUSTIBLE

TOP OF ENCLOSURE

NOTE: JOINT COMPOUNDS AND TAPES THAT ARE RESILIENT

TO HEAT AND CRACKING SHOULD BE USED WHEN TAPING

AND MUDDING SEAMS.

6"

152mm *

0” IF NON-COMBUSTIBLE

FINISHING IS USED SUCH

AS BRICK AND STONE.

3"

76mm

2"

51mm

51"

1295mm

MINIMUM

PLUS RISE**

9" 229mm

TO SIDEWALL