Napoleon Fireplaces Vector 45 - LHD45 Manuel d'utilisation

Page 30

Advertising
background image

W415-0834 / E / 06.13.13

30

EN

IMPORTANT:

The LHD45 requires a minimum inside enclosure height of 56” (1422.4mm)

,

measured from the

bottom of the appliance. For temperature requirements, this area must be left unobstructed. It is recommended
that the enclosure be ventilated at the top and bottom to circulate the hot air.

5.1 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

* See “VENTING” section.

TOP OF
FIREPLACE
OPENING

SHELF

COMBUSTIBLE

0” (0mm) IF NON-
COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK AND
STONE.

NON-COMBUSTIBLE

NON-COMBUSTIBLE
MATERIAL

VENT HEAT SHIELD

1" 25mm

2" 51mm

2" 51mm

1" 25mm

6" 152mm

MIN

45 13/16"

1164mm

MIN PLUS

RISE*

56 "

1422mm

MINIMUM

ENCLOSURE

HEIGHT

30 11/16"

780mm

MIN

18 3/16"

462mm

12 1/2"

317mm

14"

356mm

25 5/16"

643mm

MIN

Advertising