Simple venting configuration (only one 90° elbow)

See graph to determine the required vertical rise V

T

for the

required horizontal run H

T

.

REQUIRED

VERTICAL RISE

IN INCHES

(MILLIMETERS)

V

T

HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS)H

T

For vent configurations requiring more than one 90° elbow, the following formulas apply:
Formula 1: H

T

< 4.2 V

T

Formula 2: H

T

+ V

T

< 24.75 feet (7.5m)

Example:
V

1

= V

T

= 6 FT (1.8m)

H

1

= 3 FT (0.9m)

H

2

= 5 FT (1.5m)

H

R

= H

1

+ H

2

= 3FT (0.9m) + 5FT (1.5m) = 8FT (2.4m)

H

O

= .03 (two 90° elbows - 90°) = .03 (180° - 90°) = 2.7FT (0.8m)

H

T

= H

R

+ H

O

= 8FT (2.4m) + 2.7FT (0.8m) = 10.7FT (3.3m)

H

T

+ V

T

= 10.7FT (3.3m) + 6FT (1.8m) = 16.7FT (5.1m)

Formula 1:

H

T

< 4.2 V

T

4.2 V

T

= 4.2 FT (1.3m) x 6 FT (1.8m) = 25.2FT (15.9m)

10.7 FT (3.3m) < 25.2FT (15.9m)

Formula 2:

H

T

+ V

T

< 24.75 FT

16.7FT (3.3m) < 24.75 FT (7.5m)

Since both formulas are met, this vent configuration is acceptable.

The shaded area within the lines represents acceptable

values for H

T

and V

T

90°

V

1

H

1

H

2

90°

Example:
V

1

= 4 FT (1.2m)

V

2

= 1.5 FT (0.5m)

V

T

= V

1

+ V

2

= 4FT (1.2m) + 1.5FT (0.5m) = 5.5FT (1.7m)

H

1

= 2 FT (0.6m)

H

2

= 1 FT (0.3m)

H

3

= 1 FT (0.3m)

H

4

= 1.5 FT (0.5m)

H

R

= H

1

+ H

2

+ H

3

+ H

4

= 2FT (0.6m) + 1FT (0.3m) + 1FT (0.3m) + 1.5FT (0.5m) = 5.5FT (1.7m)

H

O

= .03 (four 90° elbows - 90°) = .03 (360° - 90°) = 8.1 FT (2.5m)

H

T

= H

R

+ H

O

= 5.5FT (1.7m) + 8.1 FT (2.5m) = 13.6 FT (14.2m)

H

T

+ V

T

= 13.6 FT (14.2m) + 5.5 FT (1.7m) = 19.1 FT (5.8m)

Formula 1:

H

T

< 4.2 V

T

4.2 V

T

= 4.2 FT (1.3m) x 5.5 FT (1.7m) = 23.1 FT (7m)

13.6 (4.1m) < 23.1 FT (7m)

Formula 2:

H

T

+ V

T

< 24.75 FT (7.5m)

19.1 FT (5.8m) < 24.75 FT (7.5m)

Since both formulas are met, this vent configuration is acceptable.

90°

90°

90°

90°

H

1

H

2

V

1

V

2

H

3

H

4

0

5

(1.5)

15

(4.6)

20 (6.1)

100 (2540)

50 (1270)

150 (3810)

12.5

(3.8)

8 (203.2)

57 (1447.8)

147 (3733.8)

2

(0.6)

10

(3.1)

19.5

(5.9)

16.8 A

NOTE: There MUST be a 25% reduction in total horizontal length (H

T

) when using fl ex vent.