16.1B

Simple venting confi guration (only one 90° elbow)

(H

T

) < (V

T

)

For vent confi gurations requiring more than one 90° elbow, the following formulas apply:

Formula 1: H

T

< V

T

Formula 2: H

T

+ V

T

< 40 feet (12.2m)

Example:
V

1

= 3 FT (0.9m)

V

2

= 8 FT (2.4m)

V

T

= V

1

+ V

2

= 3 FT (0.9m ) + 8 FT (2.4m) = 11 FT (3.4m)

H

1

= 2.5 FT (0.8m)

H

2

= 2 FT (0.6m)

H

R

= H

1

+ H

2

= 2.5 FT (0.8m) + 2 FT (0.6m) = 4.5 FT (1.4m)

H

O

= .03 (three 90° elbows - 90°) = .03 (270° - 90°) = 5.4 FT (1.7m)

H

T

= H

R

+ H

O

= 4.5 FT (1.4m) + 5.4 FT (1.6m) = 9.9 FT (3m)

H

T

+ V

T

= 9.9 FT (3m) + 11 FT (3.4m) = 20.9 FT (6.4m)

Formula 1:

H

T

< V

T

9.9 FT (3m) < 11 FT (3.4m)

Formula 2:

H

T

+ V

T

< 40 FT (12.2m)

20.9 FT (6.4m) < 40 FT (12.2m)

Since both formulas are met, this vent confi guration is acceptable.

See graph to determine the required vertical

rise V

T

for the required horizontal run H

T

.

The shaded area within the lines represents

acceptable values for H

T

and V

T

0

2.5

(0.8)

5

(1.5)

7.5

(2.3)

10

(3.1)

12.5

(3.8)

15

(4.6)

40 (12.2)

10 (3.1)

20 (6.1)

30 (9.1)

17.5

(5.3)

20

(6.1)

39 (11.9)

REQUIRED

VERTICAL

RISE IN FEET

(METERS)V

T

HORIZONTAL VENT RUN PLUS OFFSET IN

FEET (METERS) H

T

90°

90°

90°

V

1

V

2

H

1

H

2

3.8 HORIZONTAL

TERMINATION

NOTE: There MUST be a 25% reduction in total horizontal length (H

T

) when using fl ex vent.