Warning, 0 operating instructions – Napoleon Fireplaces High Definition 81 - HD81 Manuel d'utilisation

Page 42

Advertising
background image

W415-0687 / G / 08.26.13

42

EN

9.0 OPERATING INSTRUCTIONS

Ensure that a continuous gas fl ow is at the burner before installing the door. When lit for the fi rst time, the

fi replace will emit an odor for a few hours. This is a normal temporary condition caused by the “burn-in” of

paints and lubricants used in the manufacturing process and will not occur again. After extended periods of

non-operation such as following a vacation or a warm weather season, the fi replace may emit a slight odor for

a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window

to suffi ciently ventilate the room.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A.

Do not turn on if children or other at risk individuals are near the fi replace.

B.

This fi replace is equipped with a pilot which must be lit by hand while following these instructions

exactly.

C.

Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is

heavier than air and will settle on the fl oor.

D.

Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do

not try to repair it. Call a qualifi ed service technician. Force or attempted repair may result in a fi re or

explosion.

E.

Do not use this fi replace if any part has been under water. Immediately call a qualifi ed service

technician to inspect the fi replace and replace any part of the control system and any gas control

which has been underwater.

WHAT TO DO IF YOU SMELL GAS:

• Turn off all gas to the fi replace.

• Open windows.

• Do not try to light any appliance.

• Do not touch any electric switch; do not use

any phone in your building.

• Immediately call your gas supplier from

a neighbour’s phone. Follow the gas

supplier’s instructions.

• If you cannot reach your gas supplier,

call the fi re department.

LIGHTING INSTRUCTIONS:

1.

Stop! Read the above safety information on this label

2.

Remove batteries from the transmitter.

3.

Turn off all electrical power to the fi replace.

4. This

fi replace is equipped with an ignition device which automatically lights the pilot. Do not try to

light the pilot by hand.

5.

Open the glass door.

6.

Turn manual shutoff valve clockwise to off. Located behind the access panel.

7. Wait

fi ve (5) minutes to clear out any gas. If you smell gas including near the

fl oor, STOP! Follow “B” in the above safety information on this label. If you

don’t smell gas go to the next step.

8.

Turn manual shutoff valve counter-clockwise to on.

9.

Close the glass door.

10.

Turn on all electric power to the fi replace and re-install batteries into the

transmitter.

11.

Push the “ON” button on the transmitter. You should here an audible beep from

the receiver which indicates communication (refer to Fireplace Operation for

remote activation).

1.

Turn off all electric power to the fi replace if service is to be performed.

2.

Push in gas control knob slightly and turn clockwise to off. Do not force.

TO TURN OFF GAS:

GAS KNOB

47.3A

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH

THE GLASS DOOR OPENED OR REMOVED.

!

WARNING

Advertising