3 general information – Napoleon Fireplaces High Definition 81 - HD81 Manuel d'utilisation

Page 10

Advertising
background image

W415-0687 / G / 08.26.13

10

EN

The optional heat circulating blower is supplied with a cord.
The junction box must be electrically connected and grounded in accordance with local codes. In the absence
of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70 National
Electrical Code in the United States.
This appliance is equipped with a power back up control system. Two 1.5 volt “D” batteries (not supplied) are
required for the battery pack included in the system. Use Alkaline batteries only.

3.3 GENERAL

INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!

This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installations.

These appliances are equipped with tempered glass. Replacement glass must be obtained from your autho-
rized dealer / distributor and is identifi ed in the replacement parts list. Do not substitute materials.

This appliance is not convertible for use with other gases, unless a certifi ed kit is used.

Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Changes in fl ame appearance from “HI” to “LO” is more evident in natural gas than in propane.

Use only accessories designed for and listed with your specifi c appliance.

High Elevations
Input ratings are shown in Btu per hour and are certifi ed without de-rating up to 4,500 feet above sea level. For
Installations at the elevations above 4,500 feet (1371m) and in the absence of specifi c recommendations from
the local authority having jurisdiction, the high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000 feet (305m).

GAS SPECIFICATIONS

Model

Fuel

Gas

Control

Max.

Input

BTU/h

Min.

Input

BTU/h

Air shutter set-

ting

HD35NT Nat

IPI Hi/Lo 25,000 17,500 1/8” (3mm) Open

HD35PT Prop* IPI Hi/Lo 25,000 17,500 5/16” (8mm) Open
HD40NT Nat

IPI Hi/Lo

27,000 18,900 1/8” (3mm) Open

HD40PT Prop* IPI Hi/Lo

27,000 18,900 3/8” (10mm) Open

HD46NT Nat

IPI Hi/Lo

30,000 21,000 1/8” (3mm) Open

HD46PT Prop* IPI Hi/Lo

30,000 21,000 3/8” (10mm) Open

GAS INLET AND MANIFOLD

PRESSURES

Natural

Propane

Minimum Inlet

4.5” (11mb) w.c. 11” (27mb) w.c.

Maximum Inlet

7” (17mb) w.c.

13” (32mb) w.c.

Manifold Pressure 3.5” (9mb) w.c. 10” (25mb) w.c.

EFFICIENCY RATINGS

Model

Steady State(%)

AFUE%**

HD35NT

82.1%

77.2%

HD35PT

82.1%

77.2%

HD40NT

80.5%

76.3%

HD40PT

80.5%

76.3%

HD46NT

82.9%

79.2%

HD46PT

82.9%

79.2%

IPI - Intermittent Pilot Ignition System
* Using conversion kit
** Maximum Values
Conversions must be made by a qualifi ed service
technician using Wolf Steel specifi ed and approved parts.