Control module offers the added ability to control the fan
speed through six (6) speeds, a remotely actuated 120V
AUX outlet for the NIGHT LIGHT™ and a constantly
powered 120V outlet.

NOTE: Control module ON/OFF switch should always
be in the “ON” position. If for any reason the module
is turned “OFF”, the components plugged into the
module won’t have power.

35.15

CONSTANTLY POWERED
120V OUTLET

FAN OUTLET

120V AUX OUTLET

MAINS VOLTAGE

SUPPLY CORD

MODULE ON/OFF

SWITCH (SHOWN IN

THE ON POSITION)

COMMUNICATION

BUS (3 PIN)

The life span of the remote batteries depends on various factors: quality of the
batteries, the number of ignitions, etc.
When the transmitter batteries are low, a Battery Icon will appear on the LCD
display before all battery power is lost. When the batteries are replaced this icon will
disappear.
Not applicable when plugged into 110V.
When the receiver batteries are low, no “beep” will be emitted from the receiver
when it receives an ON/OFF command. This in an alert for the receiver that there’s
low battery. When the batteries are replaced the “beep” will be emitted from the
receiver when the ON/OFF key is pressed.
If the batteries of the receiver or transmitter are low, the appliance can be turned on manually by sliding the
three position slider switch on the receiver to the “ON” position. This will bypass the remote control feature
and the appliance main burner will come on if the gas valve is in the “ON” position.

35.13A

76

°F

If the receiver is equipped with batteries they will enable fl ame height control or ON/OFF function to control

the fi replace during a power failure. Refer to “APPLIANCE OPERATION” section when communications

between receiver and transmitter have been lost. The receiver will emit a “beep” sound to confi rm

programming has been successful once power is restored. During a power failure, if the fi replace was on, the

fl ame height will stay at the setting prior to the failure. If off when the failure occurs and then turned on, the

fl ame height will come on at “HI”. The fl ame height can then be controlled by the remote.

35.14A

8.10 LOW BATTERY / MANUAL BYPASS

8.11 IN THE EVENT OF A POWER FAILURE