Warning – Napoleon Fireplaces Madison - GD80 Manuel d'utilisation

Page 48

Advertising
background image

48

W415-0695 / D / 08.13.12

This unit is equipped with a spark module that will pro-
vide the spark to pilot when the pilot knob is pushed in.
It will be necessary to install the “AAA” battery supplied.
Install and replace batteries as noted below:

A.

Open the right control door by pulling bottom
portion away from magnet catch.

B.

Remove the hearth strip by lifting up and away
from unit.

C.

The spark module is located in the front right
corner of the unit (see photo below).

D.

Disengage the battery compartment door from the top of module.

E.

Replace battery and re-install compartment door.

11.6 “AUTO SPARK” BATTERY REMOVAL

11.7 CARE OF GLASS

5.1

DO NOT CLEAN GLASS WHEN HOT! DO NOT USE
ABRASIVE CLEANERS TO CLEAN GLASS.

Buff lightly with a clean dry soft cloth. Clean both sides
of the glass after the fi rst 10 hours of operation with a
recommended fi replace glass cleaner. Thereafter clean
as required. If the glass is not kept clean permanent
discoloration and / or blemishes may result.

HOT GLASS WILL

CAUSE BURNS.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN

TO TOUCH GLASS.

!

WARNING

11.8 RESTRICTING VERTICAL VENTS

77.3

Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must
be restricted using a restrictor vent kit. Refer to “ACCESORIES” in the “REPLACEMENTS” section for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating
a more traditional gentle fl ame appearance. Specifi c instructions are included with the kit.