Napoleon Fireplaces Madison - GD80 Manuel d'utilisation

Page 26

Advertising
background image

26

W415-0695 / D / 08.13.12

5.1 MINIMUM CLEARANCE TO COMBUSTIBLES

Minimum clearance to combustible construction from appliance and vent surfaces:

Non combustible framing:
Top

0” to stand-offs.

Combustible framing:
Sides, back, bottom of the unit

0” to stand-offs

Non combustible fi nishing:
Top

18” to top of appliance opening

Sides

5 3/8” to sides of appliance opening

Combustible fi nishing:
Bottom

0” to bottom edge of appliance

Enclosure top

72” from the bottom of appliance

Recessed depth

29 1/4”

Vent pipe**

2” all around

Ceiling

90” from bottom of unit

**HORIZONTAL VENT SECTIONS:

A minimum clearance of 2" all around the vent pipe on all horizontal runs

to combustibles is required except for clearances in appliance enclosures. Use fi restop spacer W010-1800
(supplied).

**VERTICAL VENT SECTIONS:

A minimum of 1" all around the vent pipe on all vertical runs to combustibles

is required except for clearances in appliance enclosures. Use fi restop spacer W500-0367 (not supplied).

104

3 /4"

48

3 /4"

74"

1"

MIN

1"

MIN

48 3/4"

29 1/4"

48 3/4"

29 1/4"

10"

MIN

48 3/4"