12 in the event of a power failure, 13 fan control module, 14 timed blower – Napoleon Fireplaces Tureen™ - GD82T-TE Manuel d'utilisation

Page 39: 11 low battery / manual bypass

Advertising
background image

39

W415-0769 / A / 12.10.10

8.12 IN THE EVENT OF A POWER FAILURE

If the receiver is equipped with batteries they will enable fl ame height control, ON/OFF or thermostat
function to control the fi replace during a power failure. Refer to “FIREPLACE OPERATION” section when
communications between receiver and transmitter have been lost. The will receiver emit a “beep” sound to
confi rm programming has been successful once power is restored. During a power failure, if the fi replace was
on, the fl ame height will stay at the setting prior to the failure. If off when the failure occurs and then turned on,
the fl ame height will come on at “HI”. The fl ame height can then be controlled by the remote.

35.14

8.13 FAN CONTROL MODULE

Control module offers the added ability to control the fan
speed through six (6) speeds, a remotely actuated 120V
AUX outlet for the NIGHT LIGHT™ and a constantly
powered 120V outlet.

NOTE: Control module ON/OFF switch should always
be in the “ON” position. If for any reason the module
is turned “OFF”, the components plugged into the
module won’t have power.

35.15

CONSTANTLY POWERED
120V OUTLET

FAN OUTLET

120V AUX OUTLET

MAINS VOLTAGE

SUPPLY CORD

MODULE ON/OFF

SWITCH (SHOWN IN

THE ON POSITION)

COMMUNICATION

BUS (3 PIN)

8.14 TIMED BLOWER

Your remote system may have a built in timer (in thermostat mode) that enables the blower to cycle on and
off automatically when the burner turns on and off. With the remote control fan speed preset at the preferred
speed, the blower will come on approximately 5 minutes after the main burner comes on and will shut off
approximately 12 minutes after the burner shuts off.
This time delay is designed to maximize the blower distribution of heated air.
If at any time the burner re-ignites before the twelve minutes are over, the fan will continue to run.

NOTE: At any time in the sequence, the blower can be manually turned on/off using the remote
control.

35.19A

8.11 LOW BATTERY / MANUAL BYPASS

The life span of the remote batteries depends on various factors: quality of the
batteries, the number of ignitions, the number of charges to the room thermostat set
point, etc.

When the transmitter batteries are low, a Battery Icon will appear on the LCD
display before all battery power is lost. When the batteries are replaced this icon will
disappear.

Not applicable when plugged into 110V.
When the receiver batteries are low, no “beep” will be emitted from the receiver
when it receives an ON/OFF command. This in an alert for the receiver that there’s low battery. When the
batteries are replaced the “beep” will be emitted from the receiver when the ON/OFF key is pressed.

If the batteries of the receiver or transmitter are low, the appliance can be turned on manually by sliding the
three position slider switch on the receiver to the “ON” position. This will bypass the remote control feature and
the appliance main burner will come on if the gas valve is in the “ON” position.

35.13

76

°F

ON

Advertising