W415-0769 / A / 12.10.10

5.0 FRAMING

!

WARNING

RISK OF FIRE!

IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING

IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE

APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH

ANY OTHER OUTSIDE WALL OF A HOME. THIS WILL ENSURE THAT CLEARANCE TO COMBUS-

TIBLES IS MAINTAINED WITHIN THE CAVITY.

DO NOT NOTCH THE FRAMING AROUND THE APPLIANCE STAND-OFFS. FAILURE TO MAINTAIN

AIR SPACE CLEARANCE MAY CAUSE OVER HEATING AND FIRE. PREVENT CONTACT WITH

SAGGING OR LOOSE INSULATION OR FRAMING AND OTHER COMBUSTIBLE MATERIALS. BLOCK

OPENING INTO THE CHASE TO PREVENT ENTRY OF BLOWN-IN INSULATION. MAKE SURE INSU-

LATION AND OTHER MATERIALS ARE SECURED.

WHEN CONSTRUCTING THE ENCLOSURE ALLOW FOR FINISHING MATERIAL THICKNESS TO
MAINTAIN CLEARANCES. FRAMING OR FINISHING MATERIAL CLOSER THAN THE MINIMUMS

LISTED MUST BE CONSTRUCTED ENTIRELY OF NON-COMBUSTIBLE MATERIALS. MATERIALS

CONSISTING ENTIRELY OF STEEL, IRON, BRICK, TILE, CONCRETE, SLATE, GLASS OR PLASTERS,

OR ANY COMBINATION THEREOF ARE SUITABLE. MATERIALS THAT ARE REPORTED AS PASSING

ASTM E 136, STANDARD TEST METHOD FOR BEHAVIOUR OF MATERIALS IN A VERTICAL TUBE

FURNACE AT 750°C AND UL763 SHALL BE CONSIDERED NON-COMBUSTIBLE MATERIALS.

MINIMUM CLEARANCE TO COMBUSTIBLES MUST BE MAINTAINED OR A SERIOUS FIRE HAZARD

COULD RESULT.

THE APPLIANCE REQUIRES A MINIMUM ENCLOSURE HEIGHT. MEASURE FROM THE APPLIANCE

BASE.

IF STEEL STUD FRAMING KITS WITH CEMENT BOARD ARE PROVIDED, THEY MUST BE

INSTALLED.

71.1

It is best to frame your appliance after it is positioned and the vent system is
installed. Use 2x4’s and frame to local building codes.

For convenience, the standoffs have been shipped fl at. Before framing,
ensure the standoffs are opened and screwed in place. It is not necessary
to install a hearth extension, but the appliance should be raised to be fl ush
with either the hearth or the fi nished fl oor.

W385-0395_A

WARNING

THE STANDOFFS HAVE

BEEN SHIPPED FLAT.

BEFORE FRAMING

ENSURE THE STANDOFFS

ARE BENT UP AND

SCREWED INTO PLACE.

ATTENTION ATENCIÓN

LAS TRABAS PERMANECEN

PLANAS DURANTE EL ENVÍO.

ANTES DE LA INSTALACIÓN,

VERIFIQUE QUE LAS TRABAS

SE PLIEGUEN HACIA ARRIBA

Y SE ATORNILLEN

CORRECTAMENTE.

LES ESPACEURS SONT

EMBALLÉS À PLAT. AVANT DE

CONSTRUIRE L'OSSATURE,

ASSUREZ-VOUS QUE LES

ESPACEURS SONT PLIÉS

ET FIXÉS EN PLACE À

L'AIDE DE VIS.

Advertising