SYMPTOM

PROBLEM

TEST SOLUTION

No gas to the

main burner;

switch is on.

Switch is defective.

-

Connect a jumper wire across the wall switch

terminals; if main burner lights, replace switch /

thermostat.

Burner ori¿ ce is blocked.

-

Remove stoppage in ori¿ ce.

Control valve faulty.

-

Replace.

Faulty valve.

-

Replace.

Burner will not

light, ignitor

sparks.

No gas at the burner.

-

Check that the manual valve is turned on.

-

Replace the valve.

Out of propane gas.

-

Fill the tank.

Ignitor will not

spark.

No spark at ignitor.

-

Check the power source. (ie. fuse, circuit breaker)

-

Check that the wire is connected to both the ignitor

and the control module.

-

Check that the spark is not jumping to ignitor cover.

-

Replace the wire if the wire insulation is broken or

frayed.

-

Replace the electrode if the ceramic insulator is

cracked or broken.

Spark gap is incorrect.

-

Spark gap should be 0.125” (1/8” approx.) from the

electrode tip to the sensor tip.

Remote wall

switch is in “OFF”

position; burner

comes on.

Wall switch is mounted

upside down.

-

Reverse.

Remote wall switch is

grounding.

-

Replace.

Remote wall switch wire

is grounding.

-

Check for ground (short); repair ground or replace

wire.

Faulty wire.

-

Replace.

42.6_2

CERAMIC

BODY

ELECTRODE

HIGH

VOLTAGE

IGNITION

CABLE

1/8”

GAP

SENSOR

38

W415-0794 / D / 06.19.11