W415-0794 / D / 05.30.11

SYMPTOM

PROBLEM

TEST SOLUTION

No gas to the
main burner;
switch is on.

Switch is defective.

-

Connect a jumper wire across the wall switch
terminals; if main burner lights, replace switch /
thermostat.

Burner orifi ce is blocked.

-

Remove stoppage in orifi ce.

Control valve faulty.

-

Replace.

Faulty valve.

-

Replace.

Burner will not
light, ignitor
sparks.

No gas at the burner.

-

Check that the manual valve is turned on.

-

Replace the valve.

Out of propane gas.

-

Fill the tank.

Ignitor will not
spark.

No spark at ignitor.

-

Check the power source. (ie. fuse, circuit breaker)

-

Check that the wire is connected to both the ignitor
and the control module.

-

Check that the spark is not jumping to ignitor cover.

-

Replace the wire if the wire insulation is broken or
frayed.

-

Replace the electrode if the ceramic insulator is
cracked or broken.

Spark gap is incorrect.

-

Spark gap should be 0.125” (1/8” approx.) from the
electrode tip to the sensor tip.

Remote wall
switch is in “OFF”
position; burner
comes on.

Wall switch is mounted
upside down.

-

Reverse.

Remote wall switch is
grounding.

-

Replace.

Remote wall switch wire
is grounding.

-

Check for ground (short); repair ground or replace
wire.

Faulty wire.

-

Replace.

42.6_2

CERAMIC
BODY

ELECTRODE

HIGH
VOLTAGE
IGNITION
CABLE

1/8”

GAP

SENSOR