Performing auto calibration – Sony STR-DA3300ES Manuel d'utilisation

Page 112

Advertising
background image

112

GB

For details on the auto calibration, see “9:
Calibrating the appropriate speaker settings
automatically (Auto Calibration)” (page 43).
Refer to “Before you perform the auto
calibration” (page 43) be
fore performing the
auto calibration.

To operate on the receiver

1

Press SHIFT, then press MENU to set
the GUI display mode to off.
The menu appears on the TV screen when
“GUI MODE” appears on the display.

2

Press AMP.
Receiver operation is enabled.

3

Press MENU.
“Auto Calibration” is displayed.

4

Press .

5

Press

V/v repeatedly to select “AUTO

CAL START?,” then press

to start

the measurement.
Measurement starts in five seconds. A
count down is displayed.

Note

While the time is counting down, stand away
from the measurement area to avoid
measurement error.

6

Measurement starts.
The measurement process will take
approximately 30 seconds. Wait until the
measurement process completes.

To cancel auto calibration, change the volume,
activate the MUTING function, switch
functions, change the setting of the
SPEAKERS switch of the receiver, or connect
headphones.

Note

You cannot measure the speaker height of the
surround speakers and the surround back speakers.
Set this value from “SP POSI.” settings in the
Speaker settings menu.

Tips

• Operations other than turning the receiver on or off

are deactivated during auto calibration.

• In the following situations, the measurements may

not be performed correctly or auto calibration
cannot be performed.
– when special speakers, such as dipole speakers

are used.

– when the multi zone function is used in zone 2.

To confirm/save auto calibration
when GUI function is turned off

1

Confirm the measurement result.
When the measurement ends, a beep
sounds and the measurement result appears
on the display.

2

Press

V/v repeatedly to select the item,

then press

.

The measurement results are saved.

Performing auto calibration

Measurement
result

Display

Explanation

When the
measurement
process
completes
properly

COMPLETE Proceed to step

2.

When the
measurement
process fails

ERROR
CODE 3x

See “Message
list after auto
calibration
measurement”
(page 48).

Item

Explanation

RETRY

Re-performs the auto
calibration.

SAVE EXIT

Saves the measurement
results and exits the setting
process.

WRN CHECK

Displays a warning
concerning the measurement
results. See “When you select
“WRN CHECK”” (page 48).

PHASE INFO

Displays the phase of each
speaker (in phase/out of
phase). See “When you select
“PHASE INFO”
”.

DIST.INFO

Displays the measurement
result for speaker distance.