Installation Instructions

ADVANCE PLANNING (cont.)

LOCATION REQUIREMENTS:
‡1RWGHVLJQHGIRURXWGRRULQVWDOODWLRQ
‡7KHLFHPDNHUPXVWEHLQVWDOOHGLQDQDUHD

protected from elements such as wind, rain, water

spray or drip. The area should be ven ti lat ed with

temperatures above 55°F (13°C) and below 110°F

(43°C). Best results are obtained between 70°F (21°C)

and 90°F (32°C).

‡7KHLFHPDNHUPD\EHFORVHGLQRQWKHWRSDQG

three sides as long as the front is un ob struct ed

for air circulation and proper op er a tion.

– Installation should be such that the ice maker

can be moved forward for ser vic ing, if necessary.

– The bottom grille on the front must be

unobstructed to provide proper air flow.

WATER SUPPLY
A cold water supply with water pressure of between

30 and 120 psi is required to operate the ice maker.

If you have questions about your water pressure, call

a licensed, qualified plumber.

ELECTRICAL REQUIREMENTS

WARNING :

(Please read carefully).

FOR PERSONAL SAFETY, THIS APPLIANCE MUST

BE PROPERLY GROUNDED. Do not remove ground

plug. Do not use an adapter. Do not use an

extension cord. Failure to follow these instructions

can result in death, fire or electrical shock.

AVERTISSEMENT :

(S’il vous lisez avec soin). POUR VOTRE SÉCURITÉ,

CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À

LA TERRE. N’enlevez pas la fiche de mise à la terre.

N’utilisez pas un adaptateur. N’utilisez pas un

cordon de rallonge. L’omission d’observer ces

directives peut entraîner la mort, l’incendie ou

l’électrocution.
Before you move your ice maker into its final

location, it is important to make sure you have the

proper electrical connection:
A 115 volt, 60 Hz., AC only, 15- or 20-amp electrical

supply, properly grounded in accordance with

the National Electrical Code and local codes and
RUGLQDQFHVLVUHTXLUHG8VHDQRXWOHWZKLFKFDQQRW

be turned off by a switch or pull chain.

5

ADVANCE PLANNING (cont.)

IMPORTANT:

This unit must NOT be on a GFCI

(Ground Fault Circuit Interrupter) equipped outlet

or nuisance tripping may occur resulting in loss of

cooling. Ice quality may be affected. If nuisance

tripping has occurred, and if the condition of the ice

appears poor, dispose of the ice.

Recommended Grounding Method
The ice maker must be grounded. The ice maker

is equipped with a power supply cord having a 3

prong grounding plug. The cord must be plugged

into a mating, 3 prong, grounding-type wall outlet,

grounded in accordance with the National Electrical

Code and local codes and ordinances. If a mating

wall receptacle is not available, one must be installed

by a qualified electrician.

DRAINING REQUIREMENTS
Determine a method of drainage. If a floor drain

is to be installed, the drain must be accurately

located. The installation of a custom door panel will

affect the drain location. See page 7 to determine the

exact location of the floor drain, front to back, with or

without a custom door panel.
A drain pump kit, ZPK2, is available and will not

interfere with placement of the ice maker.

BEFORE YOU BEGIN:
1.
If a custom panel is to be installed, follow the

instructions shown on pages 10 and 11.

–Order ZIP75 (black) panel kit.

– Order the custom panel from the cabinet

manufacturer.

–Secure the custom panel onto the ice maker.
2. The door swing is reversible. If desired, change

the door swing before installation following

instructions on page 13.

3. Slide the ice maker into the installation location.

– Open and close the door to be sure there is no

interference.

– Check to be sure the ice maker can be moved

back into the opening, flush with adjacent

cabinetry. There should be no interference with

the floor drain.

– Check to be sure the ice maker is level. The ice

maker will not operate properly if it is not level.

See page 6.