DUCT FITTINGS

Use this chart to compute maximum

permissible lengths for duct runs to

outdoors.
Note: Do not exceed maximum

permissible equivalent lengths!
Maximum duct length:

100 foot for vent hoods.
Flexible ducting:

If flexible metal ducting is used, all

the equivalent feet values in the table

should be doubled. The flexible metal

duct should be straight and smoot

and extended as much as possible.

Do NOT use flexible plastic ducting.
Note: Any home ventilation system,

such as a ventilation hood, may interrupt

the proper flow of combustion air

and exhaust required by fireplaces,

gas furnaces, gas water heaters and

other naturally vented systems. To

minimize the chance of interruption of

such naturally vented systems, follow

the heating equipment manufaturer’s

guidelines and safety standards such as

those published by NFPA and ASHRAE.

When applicable, install any makeup

(replacement) air system in accordance

with local building code requirements.

Visit GEAppliances.com for available

makeup air solutions.

Total

Equivalent

Quantity

Equivalent

Duct Piece

Dimensions

Length*

Used

Length

7” Round

1 ft.

straight

(per

foot

length)

3-1/4” x 12”

1 ft.

straight

(per

foot

length)

7” 90° elbow

14 ft.

7” 45° elbow

9 ft.

3-1/4” x 12”

15 ft.

90°

elbow

3-1/4” x 12”

9 ft.

45°

elbow

3-1.4” x 12”

36 ft.

90° flat elbow

7” round to

3-1/4” x 12”

1 ft.

transition

3-1/4”

x

12”

to 7” round

1 ft.

transition

7” round to

3-1/4” x 12”

4 ft.

transition 90° elbow

3-1/4” x 12” to

7” round

4 ft.

transition 90° elbow

7” round

wall cap

28 ft.

with damper

(21 ft. without damper)

3-1/4” x 12”

wall cap

26 ft.

with damper

(19 ft. without damp

7” round

39 ft.

roof

cap

Round

24

ft.

roof

vent

Total Duct Run

* Actual length of straight duct plus duct fitting

equivalent. Equivalent length of duct pieces are

based on actual tests conducted by GE Evaluatioin

Engineering and reflect requirements for good

venting performance with any ventilation hood.

9

Installation Instructions

This Hood Must Use 7” Round

Duct. It Can Transition To

3-1/4” x 12” Duct.

Using a smaller diameter duct size

will reduce performance.

Kit - JXDW1

Order kit JXDW1 if your installation

requires horizontal ducting from the

top of the hood through the back

wall and:
• You have an 8 ft. ceiling and need

to use a JXCH Series Chimney Cover,

or
• You have a 12” cabinet or 12” soffit

that the hood is to be mounted

beneath.

This kit provides a duct transition

from 7” round to 3-1/4” x 10”

rectangular for through-the-wall

venting.

Advertising
Ce manuel est liée aux produits suivants: