Warning, Installation instructions, Advance planning – GE JV936DSS Manuel d'utilisation

Page 8: Power supply, Decorative duct covers

Advertising
background image

ADVANCE PLANNING

Ductwork Planning
• This hood may be vented vertically through upper cabinets,

soffit or ceiling. A duct transition piece is supplied for vertical
exhaust. Use locally supplied elbows to vent horizontally
through the rear wall. See page 13.

• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible. FFor

satisfactory performance, duct run should not exceed 100
equivalent length for any duct configurations.

• Use metal ductwork only.
• A transition piece for 7” round duct is supplied. Use 7” round

duct or you may use 3-1/4” x 12” rectangular.

• Install a wall cap or roof cap with damper at the exterior

opening. Order the wall or roof cap and any transition
needed in advance.

• When applicable, install any makeup (replacement) air

system in accordance with local building code requirements.
Visit GEAppliances.com for available makeup air solutions.

Kit - JXDW1
Order kit JXDW1 if your installation requires horizontal ducting
from the top of the hood through the back wall and:
• You have an 8 ft. ceiling and need to use a JXCH Series

Chimney Cover, or

• You have a 12” cabinet or 12” soffit that the hood is to be

mounted beneath.

This kit provides a duct transition from 7” round to 3-1/4” x 10”
rectangular for through-the-wall venting.

Wall Framing for Adequate Support
• This vent hood is heavy. Adequate structureal support must

be provided. The hood must be secured to vertical studs in
the wall. See page 14.

• We strongly recommend that the vent hood with duct cover

be on site before final framing and wall finishing. This will
also help to accurately locate the ductwork and electrical
service.

POWER SUPPLY

IMPORTANT - (Please read carefully)

WARNING:

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY
GROUNDED.
Remove house fuse or open circuit breaker before beginning
installation.

Do not use an extension cord or adapter plug with this
appliance. Follow National electrical codes or prevailing local
codes and ordinances.

Electrical supply

This vent hood must be supplied with 120V, 60 Hz, and
connected to an individual, properly grounded branch circuit,
and protected by a 15 or 20 amp circuit breaker or time delay
fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above

requirements, call a licensed electrician before proceeding.

• Route house wiring as close to the installaton location as

possible in the ceiling, soffit or wall. See page 13 for details.

• Connect the wiring to the house wiring in accordance with

local codes.

Grounding instructions

The grounding conductor must be connected to a ground
metal, permanent wiring system, or an equipment-grounding
terminal or lead on the hood.

WARNING:

The improper connection of the

equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative if you are
in doubt whether the appliance is properly grounded..

DECORATIVE DUCT COVERS

A decorative duct cover is available to fit both model widths.
The duct cover conceals the ductwork running from the top of
the hood to the ceiling or soffit. The duct cover will fit 8 ft. to 10
ft. ceiling heights. See page 12 for details.

Installation Instructions

Advertising
Ce manuel est liée aux produits suivants: