Installation instructions, Duct cover requirements, Parts provided – GE JV936DSS Manuel d'utilisation

Page 11

Advertising
background image

Installation Instructions

11

DUCT COVER REQUIREMENTS

We recommend that the vent hood and decorative duct

cover (if used) be on site before final framing and wall

finishing. This will help to accurately locate studs, ductwork,

and electrical service. Read these instructioins to determine

if the duct cover accessory can be used for your installation

situation.

Duct Cover Accessory:

• Use the decoroative duct cover to conceal ductwork

running from the top of the hood to the ceiling.

• The duct cover accessory

consists of 2 pieces. The

outside piece is 12” high,

the inside piece is 22”.

Nested together they are

24” min. expanding to a total

maximum height of 34”.

• The outside piece can be

used alone to fill a 12”

height.

• For heights over 12”, the

ceiling bracket must be

installed to secure the cover

at the top.

To avoid unsightly gaps, plan

the hood installation height for duct cover use.
• The cover will fit a 12” min. height from the top of the

hood to the ceiling or 24” min. and expanding up to 34”

from the top of the hood to the ceiling.

THE DUCT COVER CANNOT BE USED WHEN THE DISTANCE

ABOVE THE TOP OF THE HOOD IS BETWEEN 12” AND 24”.

Review the following examples to ensure a trouble free

installation using the duct cover

accessory.
8ft. Ceilings:

The hood must be installed

at 30” above the cooking

surface (or 66” above the

floor). the duct cover will not

fit if the hood is isntalled at

a lower or higher height.

Use the outside 12” section,

discard the inside section.

9 ft Ceiling: Install the hood 24” min. and up to a maximum

of 30” above the cooking surface. The duct cover will expand

to reach ceiling height.

10 ft. Ceiling: Install the hood 32” min to 36” max. above the

cooking surface. The duct cover will expand to a maximum

of 34” above the top of the hood to meet the ceiling.

PARTS PROVIDED

Locate the hardware accessory box packed with the hood

and check contents.

Screws, wall

fasteners,

washers

Duct Transition

with Damper

2 Aluminum

Grease Filters

Filter

Support

22”

11”

12”

12”

12”

12”

8 ft. Ceiling

30”

24”

9 ft. Ceiling

30”

24”

30”

30”

10 ft. Ceiling

36” Max

32”

34”

Advertising