Installation Instructions

8

STANDARD REAR EXHAUST

9HQWHGDERYHÀRRUOHYHO

8

LEVELING AND STABILIZING YOUR
APPLIANCE

Level and stabilizing your appliance

 &DUHIXOO\ PRYH WKH DSSOLDQFH WR LWV ¿QDO ORFDWLRQ

Gently rock the appliance into position. It is important
not to damage the rubber leveling legs when moving
\RXUDSSOLDQFHWRLWV¿QDOORFDWLRQ'DPDJHOHJVFDQ

increase appliance vibration. It may be helpful to
VSUD\ZLQGRZFOHDQHURQWKHÀRRUWRKHOSPRYH\RXU
DSSOLDQFHWRLWV¿QDOSRVLWLRQ

Note: do not use washer cover to lift the unit.

2. To ensure the appliance is level and solid on all four

OHJVWLOWWKHDSSOLDQFHIRUZDUGVRWKHUHDUOHJVDUHRȺ

the ground. Gently set the appliance back down to
allow the rear legs to self adjust.

LEVEL
SIDE-TO-SIDE.

2 LEVELING LEGS

LEVEL

FRONT-TO-BACK.

CONNECTING THE DRYER TO HOUSE
VENT

RIGID METAL TRANSITION DUCT
• For best drying performance, a rigid metal transition duct is

recommended.

• Rigid metal transitions ducts reduce the risk of crushing and

kinking.

UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT
‡,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOHPHWDO

(semi-rigid) ducting can be used (Kit WX08X10077).

‡ 1HYHU LQVWDOO ÀH[LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU

other enclosed spaces.

• For many applications, installing elbows at both the dryer and

the wall is highly recommended (see illustrations on page 9).
Elbows allow the dryer to sit close to the wall without kinking
and or crushing the transition duct, maximizing drying
performance.

• Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT
• In special installations, it may be necessary to connect the

GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDO IRLOW\SH GXFW
$8/OLVWHGÀH[LEOHPHWDO IRLOW\SH GXFWPD\EHXVHG21/<LQ
LQVWDOODWLRQV ZKHUH ULJLG PHWDO RU ÀH[LEOH PHWDO VHPLULJLG 

ducting cannot be used AND where a 4” diameter can be
maintained throughout the entire length of the transition
duct.

‡,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDO IRLO

type) ducts that comply with the “Outline for Clothes Dryer
Transition Duct Subject 2158A” shall be used.

‡ 7RWDO OHQJWK RI ÀH[LEOH PHWDO GXFW VKRXOG QRW H[FHHG  IHHW

(2.4m).

• Avoid resting the duct on sharp objects.
• For best drying performance:

1. Slide one end of the duct over the clothes dryer outlet pipe.
2. Secure the duct with a clamp.
3. With the dryer in its permanent position, extend the duct to

its full length. Allow 2” of duct to overlap the exhaust pipe.
&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDVVWUDLJKW
DVSRVVLEOHIRUPD[LPXPDLUÀRZ

4. Secure the duct to the exhaust pipe with the other clamp.

ELBOW HIGHLY

RECOMMENDED

RECOMMENDED
CONFIGURATION
TO MINIMIZE
EXHAUST BLOCKAGE

NOTE: ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING

:LWKWKHDSSOLDQFHLQLWV¿QDOSRVLWLRQSODFHDOHYHORQ

top of back part of the washer lid and check it side to
side, then check front to back. Screw the front leveling
legs up or down to ensure the appliance is resting solid
on all four legs (no rocking or the appliance should
exist), turn the lock nuts on each leg up toward the base
of the unit and snug with a wrench.

Note: Keep the leg extension at minimum to prevent
excessive vibration. The farther out legs are extended, the
more the unit will vibrate.

Advertising