EXHAUST CONNECTION

THIS DRYER COMES READY FOR REAR

EXHAUSTING. IF SPACE IS LIMITED, USE

THE INSTRUCTIONS IN SECTION 9 TO

EXHAUST DIRECTLY FROM THE SIDES OR

BOTTOM OF THE CABINET.

WARNING -

TO REDUCE THE

RISK OF FIRE OR PERSONAL INJURY:

• This apliancce must be exhausted to the outdoors.
• Use only 4” rigid metal ducting for the home exhaust

duct.

• 8VH RQO\ µ ULJLG PHWDO RU 8/OLVWHG ÀH[LEOH PHWDO

(semi-rigid or foil-type) duct to connect the dryer
to the home exhaust duct. It must be installed
in accordance with the instructions found in
“Connecting The Dryer To House Vent” on page 8 of
this manual.

• Do not terminate exhaust in a chimney, a wall, a ceiling,

JDVYHQWFUDZOVSDFHDWWLFXQGHUDQHQFORVHGÀRRU

or in any other concealed space of a building. The
accumulated lint could create a

potential

¿UHKD]DUG

• Never terminate the exhaust into a common duct

with a kitchen exhaust system. A combination of
JUHDVHDQGOLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG

• 'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVW

length table. Longer ducts can accumulate lint,
FUHDWLQJDSRWHQWLDO¿UHKD]DUG

• Never install a screen in or over the exhaust duct. This

ZLOOFDXVHOLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UH

hazard.

• Do not assemble ductwork with any fasteners that

extend into the duct. These fasteners can accumulate
OLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG

• Do not obstruct incoming or exhausted air.
• Provide an access for inspection and cleaning of

the exhaust system, especially at turns and joints.
Exhaust system shall be inspected and cleaned at
least once year.

DUCT TAPE OR
DUCT CLAMP

DUCT TAPE OR
DUCT CLAMP

4" METAL DUCT CUT
TO PROPER LENGTH

EXTERNAL DUCT

OPENING

For straight line installation, connect
the dryer exhaust to the external
exhaust hood using duct tape or

clamp.

GAS
INLET
PIPE

CSA (AGA) APPROVED
NEW FLEXIBLE GAS
LINE CONNECTOR

27” DRYER EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Rigid

Metal

Rigid

Metal

56 Feet
48 Feet
40 Feet
32 Feet

0
1
2
3

42 Feet
34 Feet
26 Feet
18 Feet

Use only for short

run installations

24” DRYER EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Rigid

Metal

Rigid

Metal

43 Feet
33 Feet
24 Feet

0
1
2

36 Feet
26 Feet
16 Feet

Use only for short

run installations

EXHAUST INFORMATION (CONT.)

EXHAUST SYSTEM CHECK LIST

HOOD OR WALL CAP

• Terminate in a manner to prevent back drafts or entry

of birds or other wildlife.

Termination should present minimal resistance to
WKH H[KDXVW DLU ÀRZ DQG VKRXOG UHTXLUH OLWWOH RU QR

maintenance to prevent clogging.

Never install a screen in or over the exhaust duct. This

could cause lint build up.

• Wall caps must be installed at least 12 in. above ground

level or any other obstruction with the opening pointed

down.

SEPARATION OF TURNS

For best performance, separate all turns by at least 4

ft. of straight duct, including distance between last turn

and exhaust hood.

TURNS OTHER THAN 90º

• One turn of 45º or less may be ignored.

• Two 45º turns should be treated as one 90º turn.

• Each turn over 45º should be treated as one 90º turn.

SEALING OF JOINTS

• All joints should be tight to avoid leaks. The male end of

each section of duct must point away from the dryer.

• Do not assemble the ductwork with fasteners that

extend into the duct. They will serve as a collection

point for lint.

• Duct joints can be made air and moisture-tight by

wrapping the overlapped joints with duct tape.

• Horizontal runs should slope down toward the outdoors

1/4 inch

per foot

INSULATION

Duct work that runs through an unheated area or is

near air conditioning should be insulated to reduce

condensation and lint build-up.

• For every extra 90° elbow, reduce the allowable vent

system length by 10 ft.

• Two 45° elbows will be treated like one 90° elbow. For the

side exhaust installations, add one 90° elbow to the chart.

• The total vent system length includes all the straight

portions and elbows of the system (transition duct
included).