Installation Instructions

4

Minimum Clearance Other Than Alcove or Closet Installation

Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and rear. Consideration

must be given to provide adequate clearance for installation and service.

INTERNAL DUCT
OPENING

CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.

WALL

1

PREPARING FOR INSTALLATION

OF NEW APPLIANCE

DISCONNECTING GAS

REMOVING LINT FROM WALL
EXHAUST OPENING

• Remove and discard existing plastic or metal foil

transition duct and replace with UL listed transition duct.

DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD TRANSITION DUCTING
MATERIAL. REPLACE WITH NEW
CSA(AGA) APPROVED FLEXIBLE
GAS LINE CONNECTOR AND UL
APPROVED TRANSITION DUCT.

TURN GAS
SHUT-OFF VALVE
TO THE OFF
POSITION.

WARNING -

NEVER REUSE OLD

FLEXIBLE CONNECTORS.

7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNVDQG
SHUVRQDO LQMXU\ $OZD\V XVH QHZ ÀH[LEOH FRQQHFWRUV

when installing gas appliances.

TILT THE APPLIANCE
SIDEWAYS AND REMOVE
THE FOAM SHIPPING PADS
BY PULLING AT THE SIDES
AND BREAKING THEM AWAY
FROM THE APPLIANCE LEGS.
BE SURE TO REMOVE ALL OF
THE FOAM PIECES AROUND
THE LEGS.

After the machine is in the home,

remove remaining packing material/

carton from washer.
DO NOT REMOVE SHIPPING ROD AT

THIS TIME.
Remove styrofoam block. Remove the

bag containing the Washer hoses and

parts parts from tub. Put styrofoam

block back in tub opening to hold tub

in place during the rest of installation.

0RYH ZDVKHUFORVH WR ¿QDOSRVLWLRQ

Make sure there is at least a 24”

clearance on right side of washer to

remove shipping bar. PULL SHIPPING

BAR OUT USING YELLOW PLASTIC

HANDLE. Keep bar so it can be

reinstalled if washer is ever moved

again.

2

GAS REQUIREMENTS

WARNING

• Installation must conform to local codes and

ordinances, or in their absence, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
Natural Gas and Propane Installation Code, CSA
B149.1

• This gas dryer is equipped with a Valve & Burner

Assembly for use only with natural gas. Using
conversion kit WE25M73 for 24” Models or
WE25M74 for 27” Models, your local service
organization can convert this dryer for use with
propane (LP) gas. ALL CONVERSIONS MUST BE
MADE BY PROPERLY TRAINED AND QUALIFIED
PERSONNEL AND IN ACCORDANCE WITH LOCAL
CODES AND ORDINANCE REQUIREMENTS.

• The appliance must be disconnected from the gas supply

piping system during any pressure testing of that system
at a test pressure in excess of 0.5 PSI (3.4 KPa).

• The appliance must be isolated from the gas supply

SLSLQJV\VWHPE\FORVLQJWKHHTXLSPHQWVKXWRȹYDOYH

during any pressure testing of the gas supply piping of
test pressure equal to or less than 0.5 PSI (3.4 KPa).

27” GAS SUPPLY CONNECTION

3”

3”

Note: 24” Gas supply connectionKDVDÀH[LEOH

hose thus dimensions will vary.

NEW HOME OR REMODELING FAUCETS/
DRAIN STANDPIPE/ELECTRICAL LOCATION

FLOOR

33”

42”

12”

Locate spigots,
drain standpipe
and electrical plug
in this area

Right side of
Laundry Center

Styrofoam Block

Shipping Bar

Yellow
Plastic
Handle

Washer Hoses
and Parts

Advertising