Step 6: Electrical Requirements, Connection & Grounding

A 3- or 4-conductor supply may be connected to the
terminal block.

3-WIRE LEAD CONNECTION

1. Remove upper nuts only from the terminal block

studs. Do not remove nuts which secure
range internal wiring leads.

2. Secure the neutral, grounded wire of the supply

circuit, to the center stud of the terminal block with
nut. (See Fig. 11).

3. Secure the L1 (black) and L2 (red) power leads to

the outside terminal block studs (brass colored)
with nuts.

4. Tighten nuts securely.

4-WIRE CONNECTION

1. Remove upper nuts only from the terminal block

studs. Do not remove lower nuts which
secure range internal wiring leads.

2. Remove ground strap screw and bend the strap

up as shown in Fig. 12

3. Secure the neutral wire to the center stud of the

terminal block with nut.

4. Secure the L1 (black) and L2 (red) power leads to

the outside terminal studs (brass colored) with
nuts.

5. Secure the bare copper ground lead to the range

chassis using the ground screw previously used
for the ground strap. Be sure that neutral and
ground terminals do not touch.

6. Tighten all connections securely.

Bend Ground Strap Up

³

Ground Wire

FIG. 13

³

³

L1 Black

L2 Red

FIG. 11

FIG. 12

³

L2 Red

L1 Black

Neutral White

³

³

Ground Strap

3 Wire Connection

Conductor Securement

Secure Neutral Wire