Step 4: installing anti-tip device – Thermador PD304 Manuel d'utilisation

Page 15

Advertising
background image

12

Step 4: Installing Anti-Tip Device

PD30 and PD36 Duel Fuel Ranges (Figures 8A and 8B)

Thermador Service Part No.

Qty

Description

415078

4

Screw, Phillips, #10 x 1-1/2"

487310

1

Anti-Tip Bracket, Floor-Mounted

IMPORTANT INSTALLATION
INFORMATION:

The anti-tip bracket may be attached to a solid
wood cabinet having a minimum wall thickness of 3/
4".

The thickness of the wall or floor may require use
of longer screws, available at your local hardware
store.

In all cases, at least two (2) of the bracket mounting
screws must be fastened to solid wood or metal.

Use appropriate anchors when fastening the mount-
ing bracket to any material other than hardwood or
metal.

Prepare holes at fastener locations as identified
below:

-

For walls, wall studs, or floors composed
of solid wood or metal, drill 1/8" pilot holes.

-

For walls or floors composed of drywall,
sheet-rock or other soft materials, drill 3/16"
holes to a minimum depth of 1-3/4", then tap
plastic anchors into each of the holes using a
hammer.

-

For walls or floors composed of concrete or
concrete block, drill 3/16" holes to a minimum
depth of 1-3/4", then tap concrete anchors
into each of the holes using a hammer.

-

For walls or floors having ceramic tile cover-
ing, drill 3/16" holes through the tile only, then
drill into the material behind the tile as indi-
cated immediately above.

If the range is moved to a new location, the Anti-
Tip Device must be removed and reinstalled.

Figure 8A - Mounting Anti-tip Bracket

MOUNTING ANTI-TIP BRACKET

The alternative floor mounted bracket shall be installed
as follows:

a) Place bracket on floor in position shown in Figure

8B.

b) Secure to floor or wall stud.

c) Later, when the unit is installed,the adjustable leg

will slide under the bracket.

Figure 8B

2-1/2"

³

³

from edge of range

2-1/2"

³

³

(typical -
either side)

Advertising