Step 2: Cabinet Preparation

Power Cord & Receptacle

Junction Box & Conduit

8

ELECTRICAL SUPPLY, DUAL FUEL RANGES

Installation of Dual Fuel ranges
must be planned so that the rough-
in of the junction box for the recep-
tacle or conduit connection will al-
low maximum clearance to the rear
of the unit.

When the power supply cord (not
supplied) or conduit is connected

to the mating receptacle or junction
box cover, the combined plug/re-
ceptacle or junction box cover/con-
duit connector should protrude no
more than 2-1/4" from the rear wall.
See Figure 3B.

This is especially critical if the junc-
tion box in the wall will be directly

behind the junction box on the unit
when the unit is installed. Refer to
Figure 9 on Page 15 for location of
junction box on unit. To minimize
binding when the unit is connected
to the receptacle or junction box,
orient the receptacle or conduit
connector, and slide back into posi-
tion.

FIG. 3B WALL CONNECTION