Section 6: BEFORE CALLING FOR SERVICE

20

POWER FAILURE

Do-It-Yourself Maintenance

In the event of a power failure, only the standard
burners can be lighted manually. It is necessary
to light each standard burner individually.

If the cooktop is being used when the power
failure occurs turn all of the burner control knobs
to the OFF position. The standard burners can be
lighted by holding a match at the ports and turning

the control knob to the position. Wait until the
flame is burning all the way around the burner cap
before adjusting the flame to the desired height.
The two ExtraLow® burners on the left side
cannot be used during a power failure. Be sure to
turn them OFF if a power failure occurs because
they will not turn back on until the control knobs
are turned OFF and then turned back on again.
See “What to do if you Smell Gas”, inside front
cover.

If you have low gas pressure, contact your gas
company.

Intermittent or Constant Igniter Sparking

• Intermittent or constant sparking of the gas

surface burners can result from a number of
preventable conditions. Eliminate these
conditions as indicated in the chart.

SYMPTOM

CAUSE

REMEDY

Intermittent sparking

• Carefully dry or clean igniter.

• Ceramic igniter is wet or dirty.

• Clean ports on burner cap

with a wire, a needle or
straightened paper clip.

• Burner ports are clogged.

More than four clicks of
igniter before lighting

• Align burner cap properly on

burner base.

• Improper fit of burner cap onto

burner base.

Constant Sparking

• Refer to Installation

Instructions. Have a qualified
electrician ground the
cooktop properly.

• Cooktop is not properly

grounded.

• Refer to Installation

Instructions. Have a qualified
electrician ground the
cooktop properly.

• Electrical power supply is

incorrectly polarized.

Advertising