Location Requirements

The water heater design has been tested by CSA

International and complies with ANSI Z21.10.1, Section

2.35 Flammable Vapors Resistance. In garage installation

avoid damage to your water heater by installing a vehicle

stop as shown in figure below. Check state and local/

provincial codes for requirements prior to installation.

Important: The water heater should be located in

an area where leakage of the tank or connections will

not result in damage to the area adjacent to the water

heater or to lower floors of the structure. Due to the

normal corrosive action of the water, the tank will

eventually leak after an extended period of time.

Also any external plumbing leak, including those

from improper installation, may cause early failure

of the water tank due to corrosion if not repaired.

A qualified service technician should be contacted

for repairs. A suitable metal drain pan should be

installed under the water heater as shown below, to

help protect the property from damage which may

occur from condensate formation or leaks in the piping

connections or tank. The pan must limit the water level

to a maximum depth of 1-3/4” (4.45 cm) and be at least

two inches (5 cm) wider than the heater and piped to an

adequate drain. Locate the water heater near a suitable

indoor drain. Outside drains are subject to freezing

temperatures which can obstruct the drain line. The

piping should be at least 3/4” (1.91 cm) ID and pitched

for proper drainage. Under no circumstances will the

manufacturer or seller of this water heater be held liable

for any water damage which is caused by your failure to

follow these instructions.

The water heater should be located in an area not sub-

ject to freezing temperatures. Water heaters located in

unconditioned spaces (i.e., attics, basements, etc) may

require insulation of the water piping and drain piping

to protect against freezing. The drain and controls must

be easily accessible for operation and service. Maintain

proper clearances as specified on the data plate.

Figure 1: Garage Installation

Do not store or use gasoline or other

flammable vapors and liquids in the vicinity
of this or any other appliance. Storage of or
use of gasoline or other flammable vapors
or liquids in the vicinity of this or any other
appliance can result in serious injury or death.

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

This water heater is not certified for installation in mobile

homes.

Site Location

Select a location near the center of the water piping

system. The water heater must be installed indoors

and in a vertical position on a level surface. DO NOT

install in bathrooms, bedrooms, or any occupied room

normally kept closed. Note: The water heater may be

installed in a closet with a door off a bedroom or bath-

room providing the units are installed and vented per

the manufacturer’s instructions.

Consider the inlet and exhaust vent system piping

when selecting the water heater location. The venting

system must be able to run from the water heater to

the termination with a minimal length and number of

elbows. Input rates are reduced as vent system length

increases. The venting system must comply with the

requirements set forth in the venting section of this

manual.

Locate the water heater near the existing gas piping.

If installing a new gas line, locate the water heater to

minimize the pipe length and elbows.

Important: Air for combustion and ventilation must not

come from a corrosive atmosphere. Any failure due to cor-

rosive elements in the atmosphere is excluded from war-

ranty coverage.
Note: The water heater must be installed according to all

state and local/provincial codes or in absence of the state

and local/provincial codes with the “National Fuel Gas

Code”, ANSI Z223.1 (NFPA 54)-current edition. Canadian

installations must be performed in accordance with CAN/

CSA-B149.1-current edition.