Gas valve, Removing the gas valve, Replacing the gas valve – Polaris PC 175-50 3NV Manuel d'utilisation

Page 25

Advertising
background image

25

MAINTENANCE OF YOUR WATER HEATER

3 Month Inspection

At least every 3 months, a visual inspection should be

made of the combustion air inlet as well as the exhaust and

water piping. Check the water heater for the following:

Obstructions, damage, or deterioration in the venting
system. Make sure the exhaust and combustion air
supplies are not obstructed.

Leaking or damaged water and gas piping.

Presence of flammable or corrosive materials in the
installation area.

Presence of combustible materials near the water
heater.

Important: Verify proper operation after servicing this water

heater.

Gas Valve

The gas valve on this water heater has been permanently

set at the factory for proper operation. No field adjustments

are needed and none should be performed.

Removing the Gas Valve

Removal and replacement of the gas regulator valve

involves the disconnection of gas piping and electrical

leads. This procedure must be performed by a qualified

service technician.
Important: When removing the gas valve, do not use a

pipe wrench or vise to grip the body. Do not apply any force

to the gas valve or the cast flange fitting on the inlet side

of the gas valve (see figure 25.) Such force may break or

crack these components.
1. Turn temperature dial counterclockwise to the lowest

setting and turn off electrical power to appliance.

2. Shut off the gas at the manual shut-off valve on the

gas supply line. See figure 19 for reference. Remove

the access door.

3. Disconnect the gas piping connection just outside

the base of the water heater . Note: Use a second

pipe wrench on the gas piping inside the skirt to avoid

cracking the gas valve or the flange fitting.

4. Remove the pressure tap from the gas valve (see

figure 25). The hose should not be disconnected.

5. Remove the Phillips head screw holding the electrical

plug and remove electrical plug from the gas valve.

6. Remove the three T-25 Torx head brass screws that

attach the gas valve to the venturi manifold, using

the T-25 Torx wrench supplied with the gas valve kit

(model VK8115V, part number 6903775.)

7. Remove the gas valve from the unit keeping the

rubber gasket with the gas valve .

8. Remove the flange from the gas inlet side of the valve

by removing the four (4) attachment screws.

Figure 25

Replacing the Gas Valve

Important: The rubber gasket that seals the gas valve to

the venturi manifold must be used (previous gaskets may

be reused, if in good condition). Make sure the gasket is

properly inserted into the recess on the gas valve prior to

installation (see figure 25 for exact placement of the rubber

gasket).

1. Remove the O-ring from the flange (removed from the

old gas valve) and replace it with the one provided

in the gas valve kit (model VK8115V, part number

6903775.)

2. Reattach the elbow flange to the gas valve. Tighten all

four screws securely.

3. Place the three T-25 Torx screws through the proper

holes in the venturi manifold flange. See figure 25.

4. Properly install a new rubber gasket (provided) as

shown in figure 25.

5. Position the gas valve and start all three screws

(projecting downward from the venturi manifold) into

the gas valve. A T-25 Torx wrench has been provided

in the gas valve replacement kit (model VK8115V, part

number 6903775.)

Note: All three T-25 Torx screws must be properly tightened

to secure the seal between the gas valve and the venturi

manifold.
6. Reconnect the pressure tap to the port on the new gas

valve (see figure 25).

7. Reconnect the external gas supply line to the gas pip-

ing on the gas valve. Be sure to use approved Teflon

tape or pipe joint compound suitable for gas piping.

Note: Use a second pipe wrench on the gas piping inside

the skirt to avoid cracking the gas valve or the cast fitting.
8. Reconnect the electrical plug to the gas valve and

secure it with the screw provided.

9. Turn gas supply on and check for leaks. Use a chlo-

ride-free soap and water solution (bubbles forming

indicate a leak) or other approved method. All leaks

must be fixed immediately.

10. Be sure tank is completely filled with water before re-

storing power to the water heater. Follow operating

instructions on Page 23.

11. Ensure proper operation of the water heater, then rein-

stall the access door.

If additional information is required, contact the Product

Service and Support Group through our website:

[email protected].