John Deere AC2-8E Manuel d'utilisation

Page 18

Advertising
background image

18

Portable Electric Air Compressor Manual

TROUBLESHOOTING

SYMPTOM

PROBABLE CAUSE

REMEDY

Excessive oil consumption or oil in

hose.

Restricted air intake filter.

Crankcase overfilled with oil.

Wrong viscosity.

Plugged oil dipstick vent.

Oil leaks.

Worn piston rings or scored

cylinder.

Clean or replace.

Do not incline the air compres-

sor more than 10° in any direction

while running.

Drain oil. Refill to proper level with

SAE-30W non-detergent oil.

Drain oil. Refill to proper level with

SAE-30W non-detergent oil.
Clean.

Tighten pump bolts to torque stated

in Parts List, or replace gaskets.

Contact your Customer Service.

Oil has milky appearance.

Water in oil due to condensation.

Change oil and move air

compressor to a less humid envi-

ronment.

Unit runs backward.

Reversed wiring.

Contact qualified electrician.

Moisture in discharge air.

Condensation in air tank caused

by high level of atmospheric hu-

midity.

Run air compressor a minimum of

one hour to prevent condensation

buildup. Drain air tank after every

use. Drain air tank more often in

humid weather and use an air line

filter.

When in the Start/Stop Option,

motor runs continuously.

Motor/Pressure Switch does not

shut off motor when air compres-

sor reaches "cut-out" pressure and

safety relief valve activates.

Air compressor is incorrectly

sized.

Move the Motor/Pressure Switch

to the "OFF" position. If the motor

does not shut off, unplug the air

compressor. If the electrical con-

tacts are welded together, replace

the pressure switch.
Limit the air pressure to the capac-

ity of the air compressor. Either

use a smaller tool or a larger air

compressor.

Air compressor on unlevel surface.

Advertising