Maintenance instructions, Warning – John Deere AC2-8E Manuel d'utilisation

Page 15

Advertising
background image

Portable Electric Air Compressor Manual

15

MAINTENANCE INSTRUCTIONS

Read the instruction manual before performing maintenance. The follow-

ing procedures must be performed when stopping the air compressor for

maintenance or service.

1. Turn off air compressor.

2. Disconnect Power Cord from main power supply.

3. Open all drains.

4. Wait for the air compressor to cool before starting service.

WARNING

RISK OF BODILY INJURY!
Never assume the air

compressor is safe to work

on just because it is not

operating. It could restart

at any time!

*The pump oil must be changed after the first 50 hours of operation and every

200 hours or 3 months, whichever comes first.

Every two years, an Authorized Service Technician should check the check

valve, intake valves and delivery valves.

AC Ele. Maintenance Chart

MAINTENANCE CHART

PROCEDURE

DAILY

WEEKLY

MONTHLY

200 HOURS

Check pump oil level

X

Oil leak inspection

X

Drain condensation in air tank (s)

X

Inspect guards/covers

X

Check for unusual noise/vibration

X

Check for air leaks

X

Clean exterior of compressor

X

Inspect air filter

X

Inspect belt

X

Check safety relief valve

X

Change pump oil *

X

Replace air filter

X

Advertising