John Deere AC2-8E Manuel d'utilisation

Page 13

Advertising
background image

Portable Electric Air Compressor Manual

13

INITIAL SET-UP:
1. Read safety warnings before setting-up air compressor.
2. Ensure the oil level in the air compressor pump is adequate. If low,

add SAE-30W non-detergent oil.

LOCATION:
1. In order to avoid damaging the air compressor, do not incline the air

compressor transversely or longitudinally more than 10°.

2. Place air compressor at least 12 inches away from obstacles that may

prevent proper ventilation. Do not place air compressor in an area:

-where there is evidence of oil or gas leaks.

-where flammable gas vapors or materials may be present.

-where air temperatures fall below 32°F or exceed 104°F.

-where extremely dirty air or water could be drawn into the air

compressor.

ELECTRICAL:
1. USE OF AN EXTENSION CORD IS NOT RECOMMENDED because

it could cause the compressor motor to overheat. It's preferable to use

additional air hose instead of an extension cord.

2. If use of an extension cord is unavoidable, be sure to use one heavy

enough to carry the current your compressor will draw. Minimum cord

sizes is as follows:

3. Use only a 3-wire extension cord that has a 3-blade grounding plug and

a 3-slot receptacle that will accept the plug on the compressor.

4. Examine cords before using. Do not use the compressor if its cord is

damages. Do not use a damaged extension cord.

5. Keep cords away from heat and sharp edges. Do not pull on a cord to

disconnect a plug -- grasp the plug.

6. Always shut off the compressor Pressure Switch before unplugging the

compressor.

PRE-START CHECKLIST:
1. Check oil level. Add if necessary.
2. Remove any moisture in the air compressor air tank.

NEVER attempt

to open the Air Tank Drain Valve when more than 10 PSI of air

pressure is in the air tank! Remove excessive pressure with an air

tool, then open the Air Tank Drain Valve in the bottom of the air tank.

Close tightly when drained.

3. Make sure the Motor/Pressure Switch is in the "OFF" position.
4. Make sure the Safety Relief Valve is working correctly.
5. Make sure all guards and covers are in place and securely mounted.

PREPARATION INSTRUCTIONS

WARNING

RISK OF EXPLOSION OR FIRE

CAUSING SERIOUS INJURY

OR DEATH!

Do not allow the motor or Motor/

Pressure Switch to come in

contact with flammable vapors,

combustible dust, gases or other

combustible materials. An electric

spark may cause an explosion

or fire.
When using the air compressor

for spray painting, place the air

compressor as far away from the

work area as possible, using extra

air hoses instead of extension

cords.

DANGER

RISK OF ELECTROCUTION!

Improper connection of the

equipment-grounding conductor

can result in a risk of shock or

electrocution. Check with a

qualified electrician or service

personnel if you are in doubt as

to whether the outlet is properly

grounded. Do not use any type

of adapter with this product. If

repair or replacement of the

cord or plug is necessary, do

not connect the grounding wire

to either flat blade terminal. The

wire with insulation having an

outer surface that is green with

or without yellow stripes is the

WARNING

RISK OF BODILY INJURY!

Never attempt to open the Air

Tank Drain Valve when more

than 10 PSI of air pressure is in

the air tank!

WARNING

RISK OF ELECTRICAL SHOCK!
This product must be grounded. If

there should be a malfunction or

breakdown, grounding provides

a path of least resistance for

electric current to reduce the

risk of electric shock. This

product is equipped with a cord

having an equipment-grounding

conductor and a grounding type

plug. The plug must be plugged

into an appropriate outlet that is

properly installed and grounded

in accordance with all local codes

and ordinances.

Cord Length

Wire Gauge

Up to 25 Feet

12 AWG

26 to 100 Feet

10 AWG

101 to 150 Feet

8 AWG

151 to 250 Feet

6 AWG

Advertising