16

Portable Electric Air Compressor Manual

Plug Power Cord into a grounded

outlet.
Move Motor/Pressure Switch to

"AUTO" position.

Turn unit off, wait 5 minutes, then

press Motor Thermal Overload until

click is heard.
Reset circuit breaker or replace fuse

if necessary, using only "Fusetron"

type T fuses.
Check for low voltage conditions.
Disconnect any other electrical ap-

pliances from circuit or operate air

compressor on its own branch circuit.
Add oil. (See page 9 or 11)
Use additional air hose instead of

extension cord, or use proper wire

gauge and cord length. (See page

12)
Contact your Customer Service.

When Pilot Valve is set in the Start/

Stop position, motor will start au-

tomatically when air tank pressure

drops down to the "Cut-in" or "Start"

pressure of the Motor/Pressure

Switch.
Bleed the line by moving the switch

to the "Off" position.

Remove and clean or replace.
Contact your Customer Service.

Power Cord not plugged in.

Motor/Pressure Switch turned "OFF".

Motor Thermal Overload tripped on

air compressor.

Circuit breaker tripped or fuse blown

at power source.

Lack of oil in the air compressor.
Extension cord is too small.

Motor voltage does not match power

source.

Air tank pressure achieved the "Max-

imum setting" or "Stop pressure" of

the Motor/Pressure Switch.

Pressure release valve on Motor/

Pressure Switch has not unloaded

pump head pressure.
Pilot valve's check valve stuck open.
Defective motor, or Motor/Pressure

Switch.

TROUBLESHOOTING

SYMPTOM

PROBABLE CAUSE

REMEDY

Air compressor will not start.

Air compressor will not start,

but motor hums, then stops.

Extension cord too small.

Loose electrical connection.
Improper ventilation.
Oil weight too heavy.

Too many appliances being oper-

ated on same circuit.
Incorrect voltage, incorrect sized

circuit breaker, fuse or motor. De-

fective motor.
Defective Check Valve or Motor/

Pressure Switch.

Contact qualified electrician.
Move unit to well ventilated area.
Use lighter weight oil. (See pg. 9 or

11)
Use another circuit or remove excess

appliances from circuit.
Contact qualified electrician.

Replace.

Air compressor does not stop

even though the maximum

pressure allowed has been

reached.

Motor/Pressure Switch not operat-

ing correctly.

Replace.

Use additional air hose instead of

extension cord, or use proper wire

gauge and cord length. (See page

12)