Servicing the thermostat, Cycle rate adjustment – Honeywell Q682 Manuel d'utilisation

Page 24

Advertising
background image

24

69-0628B—1

M8894

ANTICIPATOR
SETTING LEVER

ANTICIPATOR
SCALEPLATE

Servicing the Thermostat

Cycle Rate Adjustment

The equipment should cycle on and off just

enough to keep the room temperature close to
the temperature lever settings.

If the thermostat seems to cycle the heating

system too fast or too slow, adjust the cycle rate
by moving the anticipator setting lever one
indicator mark at a time (Fig. 6). Observe the
heating system operation after each adjust-
ment. Increasing the anticipator setting will
decrease the cycle rate.

System

cph

Gravity air/water

1

Hot water

3

Gas/oil warm air

6

Electric warm air

9

Fig. 6—Heat Anticipator Setting.