Honeywell Q682 Manuel d'utilisation

Page 16

Advertising
background image

16

69-0628B—1

Troubleshooting (Continued)

Problem

Check

Action

No heat (continued).

— other.

Contact a qualified service technician for
assistance.

Energy savings
temperature program
12 hours off.

— program dial for proper day or

night phase.

Turn clock ahead 12 hours. Move minute hand
clockwise only.

Rooms do not warm
up at programmed
time.

— timer program for heating

system. May need more time
to warm up rooms.

Move red pin one-half hour earlier on the
program dial.

Temperature change
occurs at the wrong
time.

— program pins for correct time

locations.

Relocate pins to desired settings.

Room temperatures
are not correct.

— positions of thermostat set

point levers.

Reset to desired temperatures.

— position of subbase system

switch. 1

Move to desired operating position.

Continued